A city commissions a rooftop solar potential study. The study reports a headline figure in gigawatts. Three years later, installed capacity is a small fraction of it, and the study is quietly described as aspirational. This pattern is common enough to be worth taking apart, because the errors are systematic rather than random.
Error one: gross roof area
The simplest studies multiply built-up footprint by an assumed utilisation factor. Real roofs contain water tanks, stairwell heads, lift machine rooms, air conditioning plant, satellite dishes, parapets, drainage falls and access walkways. On dense urban housing, usable area after obstructions and setbacks is frequently under half of footprint, and the ratio varies sharply by building typology.
Error two: shading treated as an average
Shading is often applied as a blanket derating factor. But shading is geometric and time-varying: a roof shaded by a neighbouring tower between nine and eleven in the morning loses a different quantity of generation than one shaded in the late afternoon, and a small shaded fraction can disproportionately affect a string. Modelling shading hour by hour against a real surface model, including trees and neighbouring structures, changes per-roof results substantially.
Averaged shading gives you a plausible city total made of individually wrong buildings. Programmes are executed building by building.
Error three: structural and tenure reality
Many technically suitable roofs cannot host a system. The structure will not take the load without strengthening. The building is a multi-owner apartment block where common-area consent is difficult. The roof is leased, or informally occupied, or the subject of a dispute. None of this appears in imagery, and no model infers it — but a programme's realistic pipeline depends on it, so it should be estimated explicitly with a sampled survey rather than silently assumed away.
Error four: the grid was not asked
Potential aggregated to a city total ignores that generation must be injected into a specific distribution transformer on a specific feeder. Where residential density is highest, hosting capacity is often lowest. A study that does not aggregate potential to the network and compare it with hosting capacity will identify concentrations of opportunity that the network cannot accept without reinforcement.
What a defensible study looks like
Per-roof-plane geometry from a surface model rather than footprint area. Hourly ray-traced shading across the solar year. Explicit, sampled estimates of structural and tenure attrition. Aggregation to transformer and feeder with hosting capacity compared. And a published uncertainty range instead of a single headline number.
The resulting figure is smaller and considerably more useful, because it can be handed to a programme team as a target rather than a talking point.